MAIN CHARACTERISTICS
range of product
OSISENSE ATEX D
series name
STANDARD FORMAT
product or component type
LIMIT SWITCH
device short name
XCKD
sensor design
COMPACT
body type
FIXED
head type
ROTARY HEAD
material
METAL
fixing mode
BY THE BODY
movement of operating head
ROTARY
type of operator
THERMOPLASTIC SPRING RETURN ROLLER LEVER VARIABLE LENGTH
switch actuation
BY 30 D CAM
type of approach
LATERAL APPROACH 2 DIRECTIONS
electrical connection
SCREW-CLAMP TERMINALS 1 X 0.34...2 X 0.75 MM
cable entry number
1 TAPPED ENTRY M16 X 1.5 FOR CABLE GLAND INCLUDED CABLE OUTER DIAMETER 4...8 MM
number of poles
3
contacts type and composition
2 NC + 1 NO
contacts insulation form
ZB
contact operation
SNAP ACTION
number of steps
1
positive opening
WITH
minimum torque for tripping
0.1 N.M
maximum actuation speed
1.5 MS
IP degree of protection
IP66 CONFORMING TO IEC 60529
COMPLEMETARY CHARACTERISTICS
body material
ZAMAK
head material
ZAMAK
positive opening minimum torque
0.25 N.M
minimum actuation speed
0.01 MMIN
contact code designation
B300 AC-15 240 V IE = 1.5 A CONFORMING TO EN 60947-5-1
[Ithe] conventional enclosed thermal current
6 A AC
[Ui] rated insulation voltage
300 V CONFORMING TO UL 508
resistance across terminals
<= 25 MOHM CONFORMING TO IEC 60255-7 CATEGORY 3
[Uimp] rated impulse withstand voltage
4 KV CONFORMING TO IEC 60664
short-circuit protection
6 A CARTRIDGE FUSE TYPE GG
electrical durability
5000000 CYCLES DC-13 120 V 2 W <= 3600 CYCMN LOAD FACTOR 0.5 CONFORMING TO IEC 60947-5-1 APPENDIX C INDUCTIVE DC
mechanical durability
10000000 CYCLES
marking
II2 D EXTBIIIC T85 DB IP66 67
width
31 MM
height
65 MM
depth
30 MM
compatibility code
XCKD